The XC-9000 system is a fully electronic network PA system based upon the TCP/IP method. By leveraging the TCP/IP protocol, the system guarantees the proper and effective transmission of all data packages. Not just can it use existing local area network, such as LANs or the Web, to send program signals, however additionally it can also be released on a committed broadcasting network.


A single-server system can support up to 3000 terminals and allows for server plunging. There are no restrictions on the simultaneous broadcast networks, attaining real complete electronic broadcasting.


System Characteristics



Adaptable PA System Layout


The PA system architecture is easy, including service administration software program, network microphones, network amplifiers, network speakers, and various other devices.All tools is attached via the TCP/IP intranet procedure, permitting for adaptable configuration and very easy monitoring of the system, with complimentary control over broadcast material, network gadgets, and regions with the network.


Ip Paging MicrophoneIp Paging Microphone
Comprehensive Audio Administration


The audio management software program consists of built-in features for producing broadcast plans, versatile zoning, and pre-scheduled broadcasts.It sustains 24-hour programs, permitting altering settings during all the time


Versatile Audio Source Support


The system supports different forms of audio sources for sending out notifications like real-time speech and BGM playback. Audio resources can originate from digital music applications, CD/DVD players, microphones, etc. Additionally, the system provides varied features of supporting different broadcasting features such as scheduled broadcasting, zoned broadcasting, and emergency situation broadcasting.


Emergency Alarm System Combination


The system has a smoke alarm feature and can be incorporated right into a fire alarm system. When the alarm main system gets the startling signals, the cable television will transfer the signal to tools, which activates the XC-9000, sending signals to audio speakers


Users might pick to pre-programmed setups to turn on full-area or zoned alarm systems in emergencies. The alarm voices can be found in numerous kinds and could be edited satisfying demands. Customers can transform language setups, upload and edit their audio sources according to exact requirements, such as intruding alarms, fire alarms or air help alarms, etc.


Emergency Alarm System Assimilation


The system has an emergency alarm feature and can be integrated into a smoke alarm system. When the alarm main device receives the startling signals, the wire will certainly transfer the signal to devices, which causes the XC-9000, sending signals to audio speakers


Customers can pick to preset settings to trigger full-area or zoned alarm systems in emergencies. The alarm voices come in several types and might be edited providing to needs. For instance, users can change language settings, upload and edit their audio sources according to exact demands, such as intruding alarms, smoke alarm or air help alarm systems, etc





App Control for System Workflow


The system allows mobile app login and use, enabling individuals to start programs and other operations to authorized terminals via the web server software, making certain a practical and streamlined experience.


Integrated SIP Compatibility


The system not just enables SIP phones to log in, yet likewise can be attached to third-party SIP server or IPPBX, which develops a completely incorporated and suitable communication system via smooth integration into existing systems.


Open up SDK


When huge job like wise park occurs, the system gives an open SDK integrated right into third-party application systems - SPON Communications


System Facilities



Key Functions


Set up Playback


The system is able to instantly broadcast according to the set up tasks as long as customers submit the audio declare each amount of time of the day to the web server and develop a playback timetable.


Area Broadcasting


The system can randomly separate a couple of network gadgets right into various areas to play specified audio programs or send out announcements to any marked area. The volume of each gadget can be from another location readjusted.


Real-time Broadcasting


The system can relay and record radio programs or other outside audio sources in real-time, and at the exact same time transmitted them in sync.


Fire Alarm Integration


The system can be integrated with the emergency alarm system for control. When a smoke alarm signal is caused, it instantly triggers the emergency situation broadcast function and supports nearby floor alarms. It likewise enables manual emergency situation broadcasting by clicking a solitary switch.


SIP Phone Assimilation


The system can be incorporated with SIP web servers, permitting real-time speech of voice broadcasting using SIP phones to send statements anytime and anywhere.


CCTV Integration


The electronic gadgets such as IP POE Speakers adopts the global typical ONVIF procedure, which enables their voices to be relayed by means of VMS platforms. The terminals can likewise be incorporated with CCTV systems for integrated broadcast.


Main Products



Sound Administration Software XC-9000


B/S design, supports cross-platform applications.
Covers typical broadcasting system works, enabling for dividers administration.
Unified administration of terminals within the system, watching work status, recommended you read and set quantity modification, and so on.
Supports building multi-level server architectures, releasing administration according to customer geographical regions.
Supplies SDK development packages for secondary advancement and combination with other system platforms.


Network Paging Console XC-9038N


Power: DC12V/1.5 A.
Present: 4-inch touchscreen, resolution 480 * 480.
Interaction Procedures: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Frequency Response: 100Hz~ 16KHz.
Running Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Paging Console XC-9037N


Power Supply: DC12V/1.5 A.
Present: 4-inch touchscreen, resolution 480 * 480.
Communication Protocols: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Regularity Action: 100Hz~ 16KHz.
Operating Temperature level: 0~ 45 ℃.
Measurements: 144 * 144 * 34.1 mm.


Network Horn Audio Speaker GEN-6391A03


Power Supply: DC24V/2.7 A or POE.
Communication Method: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Frequency Feedback: 100Hz~ 18KHz.
Intercom: Supported, Built-in Microphone.
Running Temperature: -20~ 50 ℃.
Dimensions: 283.1 * 224.3 * 269mm.


Network Ceiling Speaker GEN-6211A03


Power Supply: DC 24V/1A or POE.
Interaction Protocols: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Frequency Response: 100Hz~ 18KHz.
Operating Temperature level: -20 to 50 ° C.
Dimensions: φ213 x 165mm.


Network Wall Surface Mount Speaker GEN-6011A03


Power Supply: DC24V/1A or POE.
Interaction Protocol: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Feedback: 100Hz~ 18KHz.
Operating Temperature: -20~ 50 ℃.
Measurements: 193x151.5 x292mm.


Network Column Audio Speaker GEN-6191A03




Power Supply: DC24V/1A or POE.
Interaction Method: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 90dB.
Regularity Action: 45Hz~ 18KHz.
Operating Temperature: -10~ 55 ℃.
Measurements: 296x140x130mm.


Network Sound Bridge GEN-3101A01


Power Supply: POE.
Communication Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 85dB.
Regularity Response: 50Hz~ 20KHz.
Operating Temperature level: -10~ 55 ℃.
Dimensions: 126x66x27mm.


Network Digital Amplifier XC-9508P


Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Communication Procedure: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Frequency Response: 60Hz~ 18KHz.
Running Temperature level: -10~ 50 ℃.
Measurements: 440x300x44mm.


Zone Combining Digital Amplifier NBS-2301


Power Supply : AIR CONDITIONING 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Interaction Protocol : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Ratio :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Frequency Response :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Running Temperature :.
10 ℃~ +50 ℃ (14 ℉~ 122 ℉)
Measurements : 483x430x88mm.


IP Interface System NAC-5003


Power Supply: AC100V~ 240V, 50/60Hz.
Communication Protocol: TCP/IP, UDP.
User interfaces: 1 Ethernet port, 32 alarm system inputs, 8 alarm system outcomes.
Running Temperature: -10~ 50 ℃.
Measurements: 483x259x44mm.


Option For College





Flexible Zoning Broadcast:


The completely network terminals can understand versatile zoning choices, enabling broadcasting notifications to different zones or specific terminals ( tools).


College Bell System:


It offers school bell system at the beginning/ending of the class - IP Paging System. Multiple circumstances can be made, including various set up broadcast jobs according to summer/winter timetable


Smoke Alarm Assimilation


It sustains assimilation with fire alarm systems, allowing smoke alarm signals to be integrated right into the PA system.


Classroom Sound Amplification


Terminals sustain day-to-day applications in classroom scenes. They can be attached to projectors or interactive whiteboard for audio amplification.


Ip SpeakerIp Paging Microphone

Smart Street Lamp/Security Post



Support SIP Procedure:


Integrated SIP protocol for smooth integration with network communication systems.


VMS Platforms Integration:


Integrated ONVIF procedure for integration with VMS systems.


Third-Party Integration:


Constructed In HTTP API for assimilation with third party platforms.


Voice Alarm System Triggering:


Integrated in alarm input user interface for setting off voice alarm systems with video cameras.


Remedy For Resort



Zone Control by Flooring:


The system offers full network settings, splitting areas relying upon various floors and control over each zone independently.


Fire Alarm System Assimilation:


The system can be incorporated with emergency alarm system, enabling combination of smoke alarm signals right into the broadcasting system.


Scheduled Broadcasting:


It sustains programmable arranged broadcasting, enabling adaptable plans according to various requirements.


Emergency situation Broadcasting:


It supports emergency situation broadcasting for the whole area, making it possible for one-click emergency situation interaction.


Solution For Manufacturing facility



Zone Broadcasting:


It enables transmitting to any area, assuring no interference in between Full Article various areas.


Alarm Triggering:


Terminals have various sort of user interfaces, enabling to trigger alarms when gotten in touch with video cameras.


All Network Devices:


Release of totally network devices considerably reduces the trouble of operating such as checking gadgets on dangerous sites, and thus safeguarding people and building.


The implementation of all network tools greatly reduces the problem of procedure and upkeep management


Integrated SIP Phones:


The system can be integrated with SIP phone and broadcast notifications using SIP phones any time and anywhere. Two-way audio talkback between SIP phones and IP POE Audio go now speakers makes it very easy for checking gadgets resting in office or other work environments.


The XC-9000 system is a fully electronic network PA system based on the TCP/IP protocol. By leveraging the TCP/IP protocol, the system ensures the proper and effective transmission of all information packets. The system sustains numerous forms of audio sources for sending notices like real-time speech and BGM playback. In addition, the system provides varied functions of supporting numerous broadcasting attributes such as arranged broadcasting, zoned broadcasting, and emergency broadcasting.


The system can be incorporated with the fire alarm system for control.